Use Any Software with Microlink Measurement and Control Devices

Engineers can use any OPC-enabled software - spreadsheets, databases, virtual instruments, etc - to communicate with the new Microlink OPC Servers for measurement and control. Let the Microlinks manage the initial data collection and use your favourite software to store, process and present the data.

Engineers can use any OPC-enabled software - spreadsheets, databases, virtual instruments, etc - to communicate with the new Microlink OPC Servers for measurement and control. Let the Microlinks manage the initial data collection and use your favourite software to store, process and present the data.

Part of Microsoft Windows, the OPC standard specifies a common software interface that eliminates the need for individual drivers for each piece of equipment. It makes it easy to combine hardware and software from many different manufacturers into one integrated system. The Microlinks' new OPC capabilities mean they can be quickly added to any OPC-enabled system - working alongside third-party hardware and software with no system-integration headaches or installation downtime.

The OPC Microlinks connect to a PC over either RS232 or RS485 cables. Modular-based they provide digital input and output, analogue input and output, timing and counting for monitoring and control of, for example, voltage, current, resistance, temperature, strain, humidity, force, pressure, level, flow, displacement, vibration, speed and concentration. They can handle almost any type of instrument and sensor.

Examples of OPC software which can now access data from the Microlinks include National Instruments' LabVIEW, Hexatec's Saturn SCADA interface and Microsoft's Excel.

Current serial Microlink users can add OPC compatibility simply by purchasing some OPC-server software from Biodata. This costs 145 (around $230 US or 230 Euros) and runs under Windows 95 and later.

For more information see http://www.microlink.co.uk/mlopc.html or contact

Biodata at the address below.

Biodata Ltd

10 Stocks Street

Manchester

M8 8QG

UK

Tel: +44 (0)161 834 6688

Fax: +44 (0)161 833 2190

E-mail: opc@microlink.co.uk

http://www.microlink.co.uk/


Contact Information
Graham Collins
Biodata
http://www.microlink.co.uk/opc.html
+44 (0)161 834 6688

Disclaimer: If you have any questions regarding information in these press releases please contact the company listed in the press release.
Please do not contact PRWeb®. We will be unable to assist you with your inquiry.
PRWeb® disclaims any content contained in these releases. Our complete disclaimer appears here.

© Copyright 1997-2008, Vocus PRW Holdings, LLC.
Vocus, PRWeb and Publicity Wire are trademarks or registered trademarks of Vocus, Inc. or Vocus PRW Holdings, LLC.

Terms of Service | Privacy Policy