Midwest Ethanol Plant Finds Unexpected $60/day Savings by Reusing Their Caustic

A Midwest Ethanol plant reaped the rewards when they installed a Ronningen-Petter self-cleaning filter on their caustic based CIP (clean in place) system. Due to an increase in production, the customer saw soaring caustic usage costs. To make matters worse, in late 2005 caustic costs had increased 60 - 70% over what they were when the system was installed. Clearly, the customer had to find a way to reuse the caustic to bring their costs down to a manageable level.

(PRWEB) March 16, 2006 -- A Midwest Ethanol plant reaped the rewards when they installed a Ronningen-Petter self-cleaning filter on their caustic based CIP (clean in place) system. Due to an increase in production, the customer saw soaring caustic usage costs. To make matters worse, in late 2005 caustic costs had increased 60 - 70% over what they were when the system was installed. Clearly, the customer had to find a way to reuse the caustic to bring their costs down to a manageable level.

Ethanol process:

As part of the ethanol production process, water, enzymes and corn are cooked and then combined in large fermentation tanks. When the fermentation part of the process is complete, these tanks are pumped out to the distillation system to separate the ethanol from the stillage, or by-product.

Because ethanol plants typically have many fermentation tanks the process is essentially continuous. The systems are optimized so that one tank is offline for cleaning every 1 - 4 hours. This allows the other tanks to be cleaned at some point along in the fermentation process.

This clean up is extremely important as it must take place in a very short time period -- typically less than one hour. It also must be done very efficiently to ensure a clean tank prior to refilling. If this is not done in the proper manner, costs escalate and product quality/safety are compromised.

Important: once contamination occurs, it is then necessary to stop the production line to determine where the infraction has occurred.

Situation:

To begin, the actual cleaning up of a fermentation tank is a three step process.

1. The tank is first drained prior to flushing. After the initial flushing, a drain is opened to allow the bulk of the solids to exit the tank.

2. The drain is then closed, and the wash water is recycled to completely flush the fermentation tank.

3. The final step is to flush the entire tank out with a 6-10% caustic stream to remove any leftover spent corn particles.

As the corn particles are collected in the caustic stream, they absorb a portion of the caustic so it becomes necessary for the ethanol plant to continuously monitor the strength of the caustic. Periodically, caustic is added through a caustic control valve to maintain peak cleaning efficiency.

Unfortunately, the spent particles in the system increased in proportions relative to the Ethanol plant's production increased. As the plant increased production, the consumption of the caustic was not accounted for, making the caustic addition rates fluctuate widely. This resulted in additional costs without necessarily benefiting the cleaning.

Ronningen-Petter Solution:

The Ethanol plant installed a Ronningen-Petter DCF-1600 Twin Self-Cleaning Industrial Filter on a recirculation loop off of the caustic make-down tank. Note: the filter could also have been sized to take the full flow from the make-down tank prior to the fermentation tanks if necessary.

The DCF filter was designed to run continuously, while the caustic solution was used intermittently when the fermentation tanks were flushed. Temperatures were typically in the 180° F range.

Interestingly, this particular Ethanol application can see high amounts of solids depending on the flushing loop and human error. The filter was able to handle the spikes of solids seen shortly after start-up of the caustic rinse loop, and was able to make it through upset conditions caused by improper valve sequencing.

Results:

Within the first week after the installation of the DCF-1600 Twin Self-Cleaning filter, caustic usage was stabilized and immediate savings were realized. After the first 60-days of operation the customer saw an average savings of $ 60.00 per day.

-- by Ask Filter Man

For questions about industrial filtration, please visit the Ask Filter Man forum at http://www.ronningen-petter.com/Ask-Filter-Man-Blog.asp.

If you would like to discuss this filtration solution with one of our highly trained Applications Specialists, please Contact Us at http://www.ronningen-petter.com/ContactUs/Contact-Us.asp.

If you would like to read more published real-world documented case studies about how our industrial filters have helped customers improve their bottom line, please visit the
Where in the World is Ask Filter Man forum at http://www.ronningen-petter.com/Where-In-The-World-Is-Ask-Filter-Man.asp.

###

Post Comment:
Trackback URL: http://www.prweb.com/pingpr.php/RmFsdS1UaGlyLUxvdmUtTWFnbi1IYWxmLVplcm8=

Technorati Tags

Bookmark -  Del.icio.us | Digg | Furl It | Spurl | RawSugar | Simpy | Shadows | Blink It | My Web


media  automotive  environment  water  process  manufacturing  screen  filtration  ethanol  waste  filter  cartridge  bag  cip  cleanable  self cleaning  contaminants  cip loop  cartridges  catalyst  refinery  industrial filter  coolant  ronningen-petter  ink  self cleaning filter  petroleum  dcf  ask filter man  water filter  mcf  fine filter  progressive ink  disposal  metallic  bags  hydroforming  catalyst protection filter  feedstock  bag filter  potato  industrial filters  mechanically cleaned filter  oil filter  vibrating  mechanically cleaned  tubular  eaton  food filter  chemicals filter  backwashing  hot fry oil  catalyst bed  magnetically coupled filter  liquid filter  cooling tower filter  tubular filter  backwashing filter  adhesives filter  batch process filter  ethanol plants  cip system  reactogard  paper filter  glue filter  chemical filter  particle filter  gas filter  pharmaceutical filters  ronningen petter  clay filter  petroleum filter  pcc filter  defoamer filter  industrial water filter  continuous process filter  ethanol processing  ethanol clean up  cartridge filter  contaminants filter  paper mill filter  paper contaminants  raw materials filter  make up water filter  self cleaning filters  paper manufacturing  debris filter  machine tool coolant  coolant filters  cartridge filters  mechanically cleaned filters  machining tools  filter media  machinery filters  bag filters  cip filter  fines filter  cyclones  clean in place filter  evaporators 

Other Releases by this Member
OPTIONS
Printer Friendly Version
Download PDF Version
Download Reader Version
Email this story to a colleague
CONTACT INFORMATION
Linda Stacy
Ronningen-Petter
269-329-7587
Email us Here
ATTACHED FILES

Clean In Place Loop Filtration Product Specs
Ronningen-Petter Clean In Place Loop Filtration Product Specs

DCF Self Cleaning Filter Flash Demo
Ronningen-Petter DCF Self Cleaning Filter Flash Demo

DCF Self Cleaning Filter Brochure
Ronningen-Petter DCF Self Cleaning Filter Brochure

DCF Self Cleaning Filter Family
Ronningen Petter DCF Self Cleaning Filter Family

ABOUT PRESS RELEASES
If you have any questions regarding information in these press releases please contact the company listed in the press release. Please do not contact PRWeb. We will be unable to assist you with your inquiry. PRWeb disclaims any content contained in these releases. Our complete disclaimer appears here.
 
Disclaimer: If you have any questions regarding information in these press releases please contact the company listed in the press release.
Please do not contact PRWeb®. We will be unable to assist you with your inquiry.
PRWeb® disclaims any content contained in these releases. Our complete disclaimer appears here.

© Copyright 1997-2008, Vocus PRW Holdings, LLC.
Vocus, PRWeb and Publicity Wire are trademarks or registered trademarks of Vocus, Inc. or Vocus PRW Holdings, LLC.

Terms of Service | Privacy Policy | Copyright